The DP Monitor is a differential pressure monitor designed specifically for filter house applications.
The apparatus is available with 2 different mounting enclosures:
- Standard ABS enclosure
- DIN Rail mounting enclosure
Grade of Protection for the Standard ABS enclosure is IP65.
Grade of Protection for the version with DIN Rail mounting is IP54.
IP65 protection rating is available as an optional feature and obtained by adding a transparent front panel.
The DP Monitor is available in two versions:
Micro DP
Model DPD (ABS Enclosure-IP65)
Model DPD-DIN (DIN Rail Mounting-IP54)
Model DPD-DIN/IP65 (Optional – DIN Rail Mounting-IP65)
- Digital alphanumeric backlit display
- Five languages easily selectable
- One set point
- Relay contact
DP Super
Model DPS (ABS Enclosure-IP65)
Model DPS-DIN (DIN Rail Mounting-IP54)
Model DPS-DIN/IP65 (Optional – DIN Rail Mounting-IP65)
- Digital alphanumeric backlit display
- Five languages easily selectable
- High set point
- Low set point
- Alarm set point
- Separate relay for set point and alarm
- 4–20 mA circuit, Active or Passive
All the units are supplied complete with two filter house sensor accessories to be mounted externally to the filter wall: one sensor tap for the dirty plenum and the other sensor tap for the clean air plenum. If installing the DP Digital as a pressure monitor with reference to the environment, you have to install just one filter house sensor and just one connection pipe.
Upon request it is possible to supply the unit in accordance with the European Directive II 2 D Ex tD A21 IP64 T70°C.